№ 03 · light
Grow light calculator
The lamp power a grow tent or a room needs to reach a target PPFD over its area.
To the inputsInput
Lamp power
314 W
600 × 1.2 / 0.85 / 2.7 = 314
- Lamp output, PPF
- 847
µmol/s
Your target PPFD compared with stage targets
Slightly above the range
Too much light
Too much light
Formula
PPF = PPFD × S / k
W = PPF / η
PPF is the light a lamp emits each second. Only part of it lands on the plants: more in a tent with reflective walls than in an open room. Efficacy says how many micromoles a lamp makes from each joule of electricity.
- PPF
- photosynthetic photon flux of the lamp, µmol/s
- PPFD
- target photon flux density at the canopy, µmol/m²·s
- S
- canopy area, m²
- k
- share of the light that reaches the canopy: 0.85 in a grow tent, 0.65 in an open room
- W
- power the lamp draws from the wall, W
- η
- efficacy, µmol/J: modern LED 2.7, budget LED 1.8, red and blue LED 1.5, T5 1.0, HPS 1.7
Reference
- Peppers, vegetative
- 400–520
µmol/m²·s - Leafy herbs
- 240–300
µmol/m²·s - Foliage plants
- 50–200
µmol/m²·s
Stage targets from the RootQ knowledge base: peppers in vegetative growth, leafy herbs at harvest, tropical foliage plants in active growth.
Example
A 120 × 100 cm tent (1.2 m²) of peppers in vegetative growth, aiming for 500
500 × 1.2 / 0.85 / 2.7 = 261
261
Opens RootQ with this calculation: sign in by email and pick your plant.
Save for my plantQuestions
Why does a room need more power than a tent?
A tent’s reflective walls send stray light back to the plants, so about 85 % of what the lamp emits reaches the canopy. In an open room much of it falls on the walls and the floor, and about 65 % does. For the same PPFD a room needs about 30 % more lamp.
Which PPFD should I aim for?
The target of the stage. In the RootQ knowledge base, peppers in vegetative growth want 400–520
Is the wattage on the box the real power?
Often not: many lamps are sold by an “equivalent” wattage. Use the power the lamp draws from the wall, from its spec sheet or a plug-in power meter, and its efficacy in µmol/J if the maker gives it.